119
Crossover Blocks
* Can contain a decimal number.
Example: GET 2 XOVR3FC 40 1 <LF>
We are asking E Desk to tell us the 3-way crossover low-pass cutoff frequency on instance ID 40.
2-way crossover:
Index1= 1 is the low-pass cutoff frequency
Index1= 2 is the high-pass cutoff frequency
3-Way crossover:
Index1 = 1 is low-pass cutoff frequency
Index1 = 2 is the lower slope of the mid cutoff frequency
Index1 = 3 is the higher slope of the mid cutoff frequency
Index1 = 4 is the high-pass cutoff frequency
4-way crossover:
Index1 = 1 is the low-pass cutoff frequency
Index1 = 2 is the lower slope of the low-mid cutoff frequency
Index1 = 3 is the higher slope of the low-mid cutoff frequency
Index1 = 4 is the lower slope of the mid-high cutoff frequency
Index1 = 5 is the higher slope of the mid-high cutoff frequency
Index1 = 6 is the high-pass cutoff frequency